Q46H/64 Dissolved Ozone Monitor

Dissolved Fluoride Monitor for drinking water and other clean water applications. This monitor conditions the sample for stable measurement and provides automatic calibration using two fluoride standards.

General Details

Water treatment processes using ozone gas have steadily increased over the past 20 years. Ozone has proven to be an extremely effective oxidant, removing organic carbon from raw water and destroying most pathogens. As a result, ozone treatment is now widely used in the semi-conductor, pharmaceutical, and food and beverage industries. In addition, many large cities are now using ozone to improve the quality of the drinking water distributed to their customers.

ATI’s Model Q46H/64 Dissolved Ozone Monitor provides an economical and reliable measurement system for water quality monitoring and controlling ozone treatment systems. With a variety of outputs including 4-20 mA analog, PID control, three adjustable relays, and digital communications, the Q46H/64 is adaptable to any ozone application.

INTERFERENCE-FREE
DISSOLVED OZONE MEASUREMENT

Q46H/64 monitors use a polarographic membraned sensor to accurately measure Ozone in water. The sensor operates much like a battery, generating current that is linearly proportional to the concentration of chlorine dioxide 6263_sensor1in solution. A Ozone permeable membrane isolates the sensor from the measured sample and insures that the measurement is interference free.

Two versions of the sensor are available, a sensor intended for installation in a flowcell and a sensor intended for submersion applications. Requiring minimal maintenance, sensors are easy to use and easy to maintain. An integral RTD provides temperature compensation and allows temperature to be displayed and transmitted from the monitor.

Submersion & Flowcell

SENSOR STABILIZATION

65_sensorpolarOzone sensors require 2 to 4 hours of stabilization time when first installed or after membrane change. ATI offers a battery powered “polarizer” that can be used to stabilize a spare sensor so it is ready to run within a few minutes of installation. Polarizers simply plug into the sensor connector and require no adjustments.

SENSOR & FLOWCELL OPTIONS

Dissolved Ozone sensors require a steady flow of sample across the membrane at the tip of the sensing assembly. ATI offers a number of options for flowcells, including the standard constant-head overflow system, a sealed flowcell for pressures up to 50 PSI, and a low-volume flowcell where low sample flow is important. A 1-½” flow tee is also available for in-line applications with reliable constant flow and pressure conditions. For simplicity of installation, complete flow control assemblies are available.

65_sensorOpt

Ominaisuudet

pH Input Option
Enables monitor to measure both ozone and pH. One analog output may be assigned to the pH measurement, allowing remote monitoring and recording of both variables.

Flexibility
Programmable range options from 0-200 PPB up to 0-200 PPM provide maximum application flexibility.

AC or DC Power Options
Power options include universal 100-240 VAC or 12-24 VDC.

Analog Output Options
Two isolated 4-20 mA outputs are standard, with an option for a third output if required. Default setting provides analog outputs for ClO2 and temperature.

PID Output
Standard PID control function assignable to one analog output.

Digital Communications
Available for either Profibus-DP, Modbus-RTU, or Ethernet-IP.

Relay Contacts
Three SPDT relays are standard, with relay functions programmable for alarm, control, or trouble indication. Three additional low power relays available as an option.

Flexible Mounting
NEMA 4X (IP-66) enclosure is suitable for wall, pipe, or panel mounting.

Clear Display
Back-lit large LCD display provides clear visibility in any lighting conditions. A scrolling second line on the display provides additional information and programming prompts.