- Home
- Tuotteet
- Ilmanlaadun mittaus
- Model T200U NOy with NumaView™ Software
Model T200U NOy with NumaView™ Software
Trace Level Chemiluminescence NO-NOy Analyzer
- General Details
- Features
- Specifications
- Applications
- Maintenance
- Documents
Trace Level Chemiluminescence NO-NOy Analyzer
The Model T200U NOy analyzer has been developed and refined specifically to address the challenges of NOy monitoring as required, for example, in the US NCore network. It uses the proven chemiluminescence principle and is coupled with a remote NOy converter via umbilical to allow measurements with a lower detectable limit of 50 ppt.
The Model T200U NOy analyzer combines a gold plated reaction cell with an enhanced performance pump, special low noise photomultiplier tube, and unique signal conditioning to provide exceptional sensitivity. In addition, a pre-reactor separates the NO-O3 reaction from background chemiluminescence to allow accurate auto-zero of the analyzer. The remote NOy converter is provided with a stainless steel, NEMA 4X (IP65) enclosure and custom sample umbilical to allow a mounting height of 10 meters. In addition, the converter features a unique purge circuit designed to remove residual calibration gas.
All T Series instruments offer an advanced color display, capacitive touch screen, intuitive user interface, flexible I/O, and built-in data acquisition capability. All instrument set up, control and access to stored data and diagnostic information is available through the front panel, or via RS232, Ethernet, or USB com ports, either locally or by remote connection.
The Model T200U NOy comes with the Numaview™ Software. NumaView™ Remote PC Software allows for a remote connection with virtual interface and data downloading capability to analyzers operating NumaView™ Software.
- Ranges: 0-5 ppb to 0-2,000 ppb, user selectable
- Independent ranges and auto ranging
- Dual Sample Conditioner included
- Large, vivid, and durable color graphics display with touch screen interface
- Ethernet, RS-232, and (optional) USB com ports
- Front panel USB connections for peripheral devices and firmware upgrades
- 8 analog inputs (optional)
- Adaptive signal filtering optimizes response time
- Temperature & pressure compensation
- 50 ppt lower detectable limit
- Catalytic ozone scrubber
- Comprehensive internal data logging with programmable averaging periods
- Ability to log virtually any operating parameter
- Two-year warranty
- External converter not shown above
Ranges | Min: 0-5 ppb Full scale Max: 0-2,000 ppb Full scale (selectable, independent NO, NOy ranges) |
Measurement Units | ppb, μg/m3 (selectable) |
Zero Noise | < 25 ppt (RMS) |
Span Noise | < 0.5% of reading (RMS) above 5 ppb |
Lower Detectable Limit | < 50 ppt |
Zero Drift | < 0.1 ppb/24 hours |
Span Drift | < 0.5% of reading/24 hours |
Response Time | < 70 seconds to 95% |
Linearity | 1% of full scale |
Precision | 0.5% of reading above 5 ppb |
Sample Flow Rate | 1800 cc/min ±200 cc/min (NO & NOy) |
Power Requirements | 100V-120V, 220V-240V, 50/60 Hz, Typical power 110W |
Analog Output Ranges | 10V, 5V, 1V, 0.1V (selectable) |
Recorder Offset | ±10% |
Included I/O | 1 x Ethernet: 10/100Base-T 2 x RS232 (300-115,200 baud) 2 x USB device ports 8 x opto-isolated digital outputs 6 x opto-isolated digital inputs 4 x analog outputs |
Optional I/O | 1 x USB com port 1 x RS485 4 x digital alarm outputs Multidrop RS232 3 x 4 – 20mA current outputs |
Operating Temperature Range | 5 – 40ºC |
Dimensions (HxWxD) | Analyzer: 7” x 17” x 23.5” (178 x 432 x 597 mm) |
Weight
Specifications are subject to change without notice.
All specifications are based on constant conditions.
|
Analyzer: 40 lbs (18 kg) NOy Bypass Pump Assembly: 28 lbs (12.7 kg) Converter with umbilical: 42 lbs (19.05 kg) External pump: 22 lbs (10 kg) |
The following table provides a list of items that need regular maintenance to ensure your product remains in good working condition.
ITEM | ACTION | FREQUENCY | CAL CHECK REQUIRED |
TEST functions | Review and evaluate | Weekly | No |
Particulate filter | Change particle filter | Weekly (if in stack system: As Needed) | No |
Zero/span check | Evaluate offset and slope | Weekly | No |
Zero/span calibration | Zero and span calibration | Every 3 months | Yes |
External zero air scrubber option | Exchange chemical | Every 3 months | No |
External dryer option | Replace chemical | When indicator color changes | No |
Ozone cleanser | Change chemical | Annually | Yes |
Reaction cell window (“optical filter” Figure 11‑6 in manual) | Clean | Annually or as necessary | Yes |
DFU filters | Change particle filter | Annually | No |
Pneumatic sub-system | Check for leaks in gas flow paths | Annually or after repairs involving pneumatics | Yes if a leak is repaired |
Reaction cell O-rings & sintered filters | Replace | Annually | Yes |
PMT Sensor Hardware Calibration | Low-level hardware calibration | On PMT/ preamp changes or if slope is outside of 1.0±0.3 | Yes |
Pump | Rebuild head | when RCEL pressure exceeds 10 in-Hg-A (at sea level) | Yes |
Inline Exhaust Scrubber | Replace | Annually | No |
NO2 converter | Replace converter | Every 3 years or if conversion efficiency drops below 96% | Yes |
Desiccant bags | Replace | Any time PMT housing is opened for maintenance | n/a |