- Home
- Tuotteet
- Savukaasumittaukset
- Durag
- DURAG D-R 220
DURAG D-R 220
Categories: Tuotteet, Savukaasumittaukset, Pölymittaukset, Durag
- General Details
- Overview
- Specification
- Downloads
- Certificate
General Details
Optical Dust and Opacity Monitor
Optical optical transmission analyzer to monitor the opacity or dust concentration in combustion and filter systems, ducts and warehouses.
Suitable for dust concentration measurement:
- at incinerators in general
- at garbage, hazardous waste and sewage sludge incinerators,
- at facilities for cement production
- at power stations with gas, oil, coal or co-firing
Suitable for measuring the opacity in the exhaust gas:
- at incinerators in general
Suitable for monitoring of filter facilities
Suitable for measurement of dust load in warehouses.
Overview
- Replaces D-R 216
- In-situ measurement, continuous operation
- Suitable for applications with variable gas speed
- Allows calibration to measure the dust concentration
- Measurement of opacity
- Qualitative dust measurements for monitoring the function of filters
- Also used in thick-walled stone / insulated ducts
- Device is not in contact with sample gas
- Long-life LED
- Hermetically sealed housing – no flue gas inlet in optics or electronics unit
- Easy installation, adjustment and maintenance
- Parameterization is possible with or without a PC locally
- Parameterization from external via RS-485 Modbus RTU possible
Specification
measurements | opacity, extinction (optical density), calibrated as dust concentration in mg/m3 |
measuring gas | air, flue gas, non flammable process gas, dust concentration typ.** 2-50… / 500 – 10.000 mg/m3 (.0044 – .087 / .22 – 4.4 gr/ft.3) |
duct diameter | 0,4 – 3,5 m / 3 – 10m / 10- 15m* (1.25 – 11.5 / 9.75 – 32.75 / 32.75 – 49.25 ft.*) |
measuring gas temperature | -20°C – 250°C / 400°C* / 600°C* (-4°F – 482°F / 752°F / 1112 °F) |
measuring gas pressure (relative to ambient pressure) | -50 to +10 hPa, others on request |
flue gas humidity | < 95% relative humidity, non condensing |
ambient temperature | -20 to +50 °C (-4°F to + 122°F), others on request |
certificates | CE, Pattern Approval Certificate PRC |
D-R 220 technical data |
|
measuring principle | measuring the optical transmission of visible light which passed a measuring path twice |
light source | LED, green 530 nm |
type | in situ, mounted at stack, device not in contact with sample gas |
system components | D-R 220 M measuring head D-R 220 R reflector D-R 220 SU supply unit accessories |
measuring ranges | 0 – 97,5% opacity 0 – 1,6 extinction |
expanded uncertainty DIN EN14181 / DIN EN ISO14956 / EN15267-3 | better than 0.013 Ext / ca. 2 mg/m3** (.00087 gr/ft.3**) at particle size 1-2mü and duct diameter = 5m (16.5 ft.) |
output ranges | 0- 25%/50%/100% opacity 0-0,2/0,4/1,6 extinction alternatively assigned to an analog output |
process connection | 2 x adjustment flange, 100mm (4in.) bolt circle, pipe ID = 59 / 83* / 105* mm (2.25 / 3.25* / 4.25* in.) |
D-R 220 M measuring head |
|
measurement outputs | 1 x 4–20 mA / 500 Ohm, isolated 1x RS 485 Modbus RTU |
status outputs | 2 relay outputs, programmable function, max. load 48V, 0.5 A |
power supply | 24VDC, 0,4A |
protection | IP65 |
dimensions (h x w x d) | ca. 210 x 300 x 380 mm (8.25 x 11.75 x 15 in.) |
weight | 2,7 kg (6 lbs.) |
material | housing: polyamide, RAL 5017, fire class B1 (UL 94 V0) purge flange: 1.4571 (316 Ti) |
D-R 220 R reflector |
|
weight | 1,6 kg (3.5 lbs.) |
material | housing: polyamide, RAL 5017, fire class B1 (UL 94 V0) purge flange: 1.4571 (316 Ti) |
D-R 220 SU supply unit |
|
dimensions (h x w x d) | ca. 210 x 300 x 380 mm (8.25 x 11.75 x 15 in.) |
purge air flow rate | max. 20 / 80 m3/h at dPtot 16 / 4 hPa |
power supply | 90-264 V, 47-63 Hz supplied D-R 220 M with 24 VDC |
protection | IP54 |
dimensions (h x w x d) | 380 x 310 x 210 mm (15 x 12.25 x 8.25 in.) |
weight | 12 kg (26.5 lbs.) |
material | stainless steel 1.4301 |
remarks | * Variants ** operating principle of the suitability of the DR 220 is designated for areas of dust sort, dust size distribution and the chimney diameter |
Downloads