COD analyser QuickCODultra

LAR Process Analysers

General Details

Online COD for every kind of water. Especially for the rough stuff.

LAR’s QuickCODultra is the ultimate online COD analyser for the determination of chemical oxygen demand (COD) suitable even for the most difficult waste water applications.

Exact Analysis. Clean, fast and accurate.

Exact Analysis. Clean, fast and accurate. In contrast to the common standard methods, which are time consuming and require dangerous reagents, the QuickCODultra uses the combustion method. It is fast and takes up the original idea of the complete consideration of, for the oxidation of the organic components contained in the water, oxygen required. This method goes without any use of dangerous and etching substances so that a high operational safty is ensured.

Another advantage of this method: The measurement results are due to the complete digestion of the unique and litigation free from chloride interference.

The real COD. Even with changing sample matrixes.

The entire raw waste water sample including all particles is directly injected into a furnace via the unique injection system. With our ULTRA high temperature method oxygen is used to digest all components. This demand is detected by a special oxygen detector so that the analyser truely measures the real oxygen demand. Even with applications with changing sample compositions the QuickCODultra reliably determines the COD.

High salt concentrations. No problem with the QuickCODultra.

This online COD analyser can handle salt concentrations up to even 300 g/l sodium chloride (NaCl). Salts that melt at the temperature of 1,200°C are vaporised by the combustion power and carried out with the carrier gas to settle in a special retrieving device.

The QuickCODultra. Ultra quick measurements and maintenance.

The measurement of the COD takes place in less than 2 minutes. This speed guarantees that very short peaks can be determined very well during a daily cycle.

The analyser’s availability is over 98%. As even in high salt applications its weekly service is about 30 minutes.

Ominaisuudet
  • Measurement range: 10 – 150 mg/l, 100 – 2,000 mg/l, 500 – 5,000 mg/l, 1,000 – 8,000 mg/l, 20,000 – 250,000 mg/l, further options available
  • Response time: 1 – 2 minutes
  • Measures the real oxygen demand
  • Highest combustion temperature (1,200°C) available on the market
  • Catalyst-free technique
  • Reliable measurement without reagents
  • No filtration necessary
  • No memory effects
  • Very low maintenance and operational costs
Applications

 

  • Waste water treatment
  • Process control

 

Options
  • FlowSampler
  • Multi-stream measurement
  • Combination with TOC and TNb detection

 

Housing
  • IP54 (Standard)
  • NEMA 4X
  • ATEX Zone I
  • ATEX Zone II